Florida has no mold law for gym saunas. Sign the petition for a mandate.

Sign the Petition

Less Than a Quart: How Little Water It Takes to Push a Room to Mold Country

Green Building Advisor runs the arithmetic nobody does: in a small apartment, under two pints of added water vapor lifts the air from a reasonable 50% relative humidity to the 70% where cool surfaces sweat and mold feeds — and an ordinary evening of showers, cooking, and dishes makes that much water several times over.

Setting: homes and indoor air generally; the arithmetic is the article’s, the gym application is ours and is labelled as such. Source score: 8/10. This page is our original summary of a published building-science article. It is general information, not legal or medical advice.

Source: Green Building Advisor, “Moisture Sources, Relative Humidity, and Mold” — moisture tables sourced within the article to Nathan Yost (3-D Building Solutions) and to the Minnesota Extension Service, University of Minnesota.

The number that reframes the subject

Mold arguments usually start with the growth itself — the stain, the smell, the sample. This article starts one step earlier, with how little water vapor a room’s air can hold before the room becomes a mold incubator, and the answer is small enough to fit in a drinking glass.

Its worked example is an 800-square-foot apartment — 6,400 cubic feet of interior space — sitting at a reasonable 50% relative humidity. The air in that apartment already holds 3.0 pints of water at 65 °F, 3.6 pints at 70 °F, and 4.4 pints at 75 °F. To push that air to 70% relative humidity, the table (sourced in the article to Nathan Yost of 3-D Building Solutions) says you need to add just 1.4 pints at 65 °F, 1.6 pints at 70 °F, or 1.8 pints at 75 °F. Less than a quart of water, total, is the entire distance between a comfortable room and a problem room.

Why 70% is the line that matters, in the article’s account: an interior RH of 70% will make just about everyone uncomfortable, and it means cooler surfaces in the home can approach the dew point — the temperature at which vapor condenses back into liquid water on the surface itself. Condensation is the delivery mechanism: air that never quite feels wet still deposits liquid water on the coldest wall, window frame, and pipe in the room, and that liquid film is what mold and dust mites live on. A room does not have to leak to be wet. It only has to breathe out more water than it exchanges away, next to one cold surface.

Where the water comes from

The article’s second table (sourced to the Minnesota Extension Service, University of Minnesota, for a family of four) prices ordinary life in pints:

The article’s conclusion follows directly: cooking dinner, eating, and then washing the dishes adds enough moisture to raise a small dwelling’s RH to levels that spell trouble. Its worked example assumes no air exchange at all — and it says plainly that this is the point. Every home, but especially an energy-efficient airtight one, needs dedicated air exchange, particularly in high-moisture areas like the kitchen and baths. Its practical advice is threefold: keep an eye on moisture sources, ventilate for moisture control, and track interior RH with an inexpensive hygrometer (about $20 in the article) rather than guessing.

Why it matters here — the gym application, in our words

The article is about homes. The arithmetic is not. A gym locker room runs the article’s two biggest sources — showers and human respiration and perspiration — continuously, at occupant densities no apartment ever reaches, in a room deliberately kept hot, and a sauna adds a third: water thrown on stones, vaporized on purpose. The defense the article names is the same one at gym scale: dedicated air exchange sized to the moisture load, and surfaces that do not sit at the dew point collecting the difference. Where that exchange is absent — where the wet room is sealed, the bench cavity is closed, and nothing dries between the morning and evening crowds — the margin this table measures is not spent once a day. It is spent before the first class ends, and the room lives past it permanently. When an operator says a locker room or sauna “just gets humid,” this table is the translation: humid is a quantity, the quantity is small, and the building either removes it or grows in it.

Tools for this job: Measure — moisture is the whole game

Pinless moisture meter

What it is: A handheld meter that reads moisture inside drywall, wood, and flooring through the surface — no pinholes, no damage. The tool that finds the wet wall behind the paint.

Why it is listed: Moisture readings are the hardest evidence to argue with. A dated photo of a meter reading on a wall turns a landlord dispute from opinion into documentation.

Its limits: Readings are relative and material-dependent — use them comparatively (wet spot vs. known-dry spot) and record both. A meter finds moisture, not mold.

Visit Pinless moisture meter →

Thermo-hygrometer / humidity data logger

What it is: A room thermometer-hygrometer; the logging kind records humidity over days and weeks instead of showing a single moment.

Why it is listed: A log beats a snapshot. Two weeks of humidity history above 60% is a document; a glance at a dial is an anecdote.

Its limits: Cheap sensors drift — sanity-check a new unit against a second one. Placement matters: measure where people live and sleep, not next to a shower door.

Visit Thermo-hygrometer / humidity data logger →

Some links in this strip are affiliate links and cost you nothing extra if you buy through one. As an Amazon Associate I earn from qualifying purchases. Affiliate money never buys scores, coverage, or silence — see our affiliate disclosure.

Read it at the source: Green Building Advisor — Moisture Sources, Relative Humidity, and Mold.

If this happened to you

Showering, training, or working in a wet room that never actually dries — fogged mirrors at opening time, condensate running before the first class? File a report and record what the room does, with times. The dated pattern is the evidence; the arithmetic above is why it matters.

Not professional advice. This page summarizes one published article’s tables and conclusions for general information; the worked example is a small apartment, as the article states. Building-specific moisture design belongs to building professionals — the article’s own advice is to measure your air and ventilate, not to guess.

THE NETWORK — ONE PUBLISHER, EVERY FRONT